Each layout brings sleeping space, a bathroom and a kitchenette into a compact, practical plan. Natural light, integrated cooling and durable surfaces support everyday comfort and maintenance.
Single, double and four-person configurations can be arranged as a low-rise compound, with circulation, shared facilities and services planned for the site. The final arrangement responds to headcount, operations and authority requirements.
| Element | Reference Specification | Performance & Project Basis |
|---|---|---|
| Structural system | Hot-dip galvanized steel frame, 275 g/m² zinc coating; hollow-core slab and lightweight concrete block. | Reference design basis: wind speed 45 m/s; seismic Zone 2A. Site-specific calculations govern. |
| External walls | 150 mm lightweight concrete panel with 50 mm stonewool insulation. | Reference U-value: 0.24 W/m²K. Confirm the complete wall assembly. |
| Roof | 200 mm stonewool insulation with GFRP waterproof liner. | Reference U-value: 0.18 W/m²K. Solar provision to be coordinated. |
| Windows & doors | Double-glazed UPVC, 6/12/6 mm Low-E glass. | Reference SHGC: 0.28. Final frame and glazing schedule by project. |
| Interior finishes | 4 mm marble-look SPC flooring, 12.5 mm gypsum ceilings and gypsum partitions. | Finish selection and tested fire classifications confirmed in material submittals. |
| Fire performance | Reference external wall and roof material classification: Class A1 under EN 13501-1. | Complete assemblies, test evidence and fire strategy require project review. |
| Acoustic performance | Reference Rw: 48 dB for walls; 45 dB for floors. | Assembly test data, junction detailing and on-site performance to be confirmed. |
| MEP coordination | Factory pre-wiring, concealed plumbing, AC provisions and service shafts. | Internal fit-out and site connections defined in the agreed responsibility schedule. |
| Corrosion protection | Galvanized and powder-coated elements. | Reference exposure category C4; select the coating system and maintenance regime for the site. |
| Service life & warranty | Reference design life: 50+ years with scheduled maintenance. | 10-year structural warranty stated in the guide; final terms are defined in the contract. |